Webcentive RISC-V Reference

mepc

Machine exception program counter

Address
0x341
Group
Machine-level CSRs
Privilege
MRW (privileged spec CSR listing, Machine Trap Handling)
Access
read/write; lowest privilege M (machine)
Address range
Standard read/write
Name in riscv-unified-db
Machine Exception Program Counter

Privileged spec: Machine exception program counter

Description

Written with the PC of an instruction on an exception or interrupt taken in M-mode.

Also controls where the hart jumps on an exception return from M-mode.

From riscv-unified-db, reformatted.

Fields

FieldBitsTypeDescription
PCRV32 31-0 / RV64 63-0RW-RH

When a trap is taken into M-mode, mepc.PC is written with the virtual address of the instruction that was interrupted or that encountered the exception. Otherwise, mepc.PC is never written by the implementation, though it may be explicitly written by software.

On an exception return from M-mode (from the MRET instruction), control transfers to the virtual address read out of mepc.PC.

Because PCs are always halfword-aligned, bit 0 of mepc.PC is always read-only 0.

Because PCs are always word-aligned, bits 1:0 of mepc.PC are always read-only 0.

When misa.C is clear, bit 1 is masked to zero. Writes to bit 1 are still captured, and may be visible on the next read with misa.C is set.

Fields from riscv-unified-db; field types computed by IDL functions there are not shown.

Specification and related pages