Webcentive RISC-V Reference

mideleg

Machine interrupt delegation register

Address
0x303
Group
Machine-level CSRs
Privilege
MRW (privileged spec CSR listing, Machine Trap Setup)
Access
read/write; lowest privilege M (machine)
Address range
Standard read/write
Name in riscv-unified-db
Machine Interrupt Delegation

Privileged spec: Machine interrupt delegation register

Description

Controls exception delegation from M-mode to HS/S-mode

By default, all traps at any privilege level are handled in machine mode, though a machine-mode handler can redirect traps back to the appropriate level with the MRET instruction. To increase performance, implementations can provide individual read/write bits within mideleg to indicate that certain exceptions and interrupts should be processed directly by a lower privilege level.

In harts with S-mode, the mideleg register must exist, and setting a bit mideleg will delegate the corresponding trap, when occurring in S-mode or U-mode, to the S-mode trap handler

When H is implemented:

(which could further be delegated to VS-mode through hideleg)

.

When ext?(:S, "> 1.9.1"):

In harts without S-mode, the mideleg register should not exist.

Note

In versions 1.9.1 and earlier , this register existed but was hardwired to zero in M-mode only, or M/U without N harts. There is no reason to require they return zero in those cases, as the misa register indicates whether they exist.

Otherwise:

In harts without S-mode, the mideleg register is read-only zero.

An implementation can choose to subset the delegatable traps, with the supported delegatable bits found by writing one to every bit location, then reading back the value in mideleg to see which bit positions hold a one.

Note

Version 1.11 and earlier prohibited having any bits of mideleg be read-only one. Platform standards may always add such restrictions.

Traps never transition from a more-privileged mode to a less-privileged mode. For example, if M-mode has delegated illegal-instruction exceptions to S-mode, and M-mode software later executes an illegal instruction, the trap is taken in M-mode, rather than being delegated to S-mode. By contrast, traps may be taken horizontally. Using the same example, if M-mode has delegated illegal-instruction exceptions to S-mode, and S-mode software later executes an illegal instruction, the trap is taken in S-mode.

Delegated interrupts result in the interrupt being masked at the delegator privilege level. For example, if the supervisor timer interrupt (STI) is delegated to S-mode by setting mideleg[5], STIs will not be taken when executing in M-mode. By contrast, if mideleg[5] is clear, STIs can be taken in any mode and regardless of current mode will transfer control to M-mode.

mideleg holds trap delegation bits for individual interrupts, with the layout of bits matching those in the mip register (i.e., STIP interrupt delegation control is located in bit 5).

For exceptions that cannot occur in less privileged modes, the corresponding medeleg bits should be read-only zero. In particular, medeleg[11] is read-only zero.

The medeleg[16] is read-only zero as double trap is not delegatable.

From riscv-unified-db, reformatted.

Fields

FieldBitsTypeDescription
SSI1

Supervisor Software Interrupt delegation

When 1, Supervisor Software interrupts are delegated to HS/S-mode.

VSSI2RO

Virtual Supervisor Software Interrupt delegation

When 1, Virtual Supervisor Software interrupts are delegated to HS-mode.

Virtual Supervisor Software Interrupts are always delegated to HS-mode, so this field is read-only one.

MSI3

Machine Software interrupt delegation

When 1, Machine Software interrupts are delegated to HS/S-mode. This is unusual but permitted. See https://github.com/riscv/riscv-isa-manual/issues/3162.

STI5

Supervisor Timer interrupt delegation

When 1, Supervisor Timer interrupts are delegated to HS/S-mode.

VSTI6RO

Virtual Supervisor Timer interrupt delegation

When 1, Virtual Supervisor Timer interrupts are delegated to HS-mode.

Virtual Supervisor Time Interrupts are always delegated to HS-mode, so this field is read-only one.

MTI7

Machine Timer interrupt delegation

When 1, Machine Timer interrupts are delegated to HS/S-mode. This is unusual but permitted. See https://github.com/riscv/riscv-isa-manual/issues/3162.

SEI9

Supervisor External interrupt delegation

When 1, Supervisor External interrupts are delegated to HS/S-mode.

VSEI10RO

Virtual Supervisor External interrupt delegation

Virtual Supervisor External Interrupts are always delegated to HS-mode, so this field is read-only one.

MEI11

Machine External interrupt delegation

When 1, Machine External interrupts are delegated to HS/S-mode. This is unusual but permitted. See https://github.com/riscv/riscv-isa-manual/issues/3162.

SGEI12RO

Supervisor Guest External Interrupt delegation

Supervisor Guest External interrupts are always delegated to HS-mode when any guest external interrupts are implemented (NUM_EXTERNAL_GUEST_INTERRUPTS is nonzero), so this field is read-only one; otherwise it is read-only zero.

LCOFI13

Local Counter Overflow Interrupt delegation

When 1, local counter overflow interrupts are delegated to (H)S-mode.

Fields from riscv-unified-db; field types computed by IDL functions there are not shown.

Specification and related pages