sireg5
Supervisor indirect register alias 5
- Address
0x156- Group
- Supervisor-level CSRs
- Privilege
SRW(privileged spec CSR listing, Supervisor Indirect)- Access
- read/write; lowest privilege S (supervisor)
- Address range
- Standard read/write
- Name in riscv-unified-db
- Supervisor Indirect Register Alias 5
Privileged spec: Supervisor indirect register alias 5
Description
Access to sireg5 from M-mode or S-mode while siselect holds a number in a
standard-defined and implemented range results in specific behavior that, for each combination of
siselect and sireg5, is defined by the extension to which the siselect value is allocated.
Ordinarily, sireg5 will access register state, access read-only 0 state, or, unless
executing in a virtual machine (covered in the next section), raise an illegal instruction
exception.
Note that the widths of siselect and sireg5 are always the current XLEN rather than SXLEN. Hence,
for example, if MXLEN = 64 and SXLEN = 32, then this register is 64 bits when the current
privilege mode is M (running RV64 code) but 32 bits when the privilege mode is S (RV32 code).
The behavior upon accessing sireg5 from M-mode or S-mode, while siselect holds a value that is
not implemented at supervisor level, is UNSPECIFIED.
It is recommended that implementations raise an illegal instruction exception for such accesses, to facilitate possible emulation (by M-mode) of these accesses.
An extension is considered not to be implemented at supervisor level if machine level has
disabled the extension for S-mode, such as by the settings of certain fields in CSR
menvcfg, for example.
From riscv-unified-db, reformatted.
Fields
| Field | Bits | Type | Description |
|---|---|---|---|
VALUE | RV32 31-0 / RV64 63-0 | RW | Indirectly Selected Register Value. The data read from or written to the register selected by the current |
Fields from riscv-unified-db; field types computed by IDL functions there are not shown.