Description

The vsstatus register tracks and controls the hart's current operating state.

It is VS-mode's version of sstatus, and substitutes for it when in VS-mode (i.e., in VS-mode CSR address 0x100 is vsstatus, not sstatus).

Unlike the relationship between sstatus and mstatus, none of the bits in vsstatus are aliases of another field.

From riscv-unified-db, reformatted.

Fields

FieldBitsTypeDescription
SDRV32 31 / RV64 63RO-H

State Dirty

Read-only bit that summarizes whether any of the vsstatus.FS, (when V is implemented: vsstatus.VS,) or vsstatus.XS fields signal the presence of some dirty state (i.e., any of them hold the value 11).

This bit is not an alias of mstatus.SD since it only reflects the state visible to VS-mode (e.g., status.FS does not affect vsstatus.SD).

UXL33-32

VU-mode XLEN

Sets the effective XLEN for VU-mode (0 = 32-bit, 1 = 64-bit, 2 = 128-bit).

Since the hart only supports VUXLEN==32, this is hardwired to 0.

Since the hart only supports VUXLEN==64, this is hardwired to 1.

SPELP23RW-HVS-mode Previous Expected Landing Pad state.

Holds the previous Expected Landing Pad (ELP) state when entering VS-mode from a trap, and is restored to ELP on SRET from VS-mode.

Defined by the Zicfilp extension.

Per the privileged architecture, accesses to sstatus.SPELP resolve to mstatus.SPELP when V=0, and to vsstatus.SPELP when V=1; the V=1 routing is handled by the H-extension CSR address remap (virtual_address on this CSR), so this field is independent state — not an alias of mstatus.SPELP.

Encoded as:

  • 0 - NO_LP_EXPECTED - no landing pad instruction expected.
  • 1 - LP_EXPECTED - a landing pad instruction is expected.
MXR19RW

Make eXecutable Readable

Makes it possible to read executable pages when loading from effective VU-mode or VS-mode (normally, executable pages are not readable).

  • When 1, load in effective VU-mode or VS-mode from pages marked readable or executable are allowed as long as the page is marked readable (or executable and status.MXR is set) in the G-stage translation.
  • When 0, load in effective VU-mode or VS-mode from pages marked executable raise a Page Fault exception (unless sstatus.MXR is also set, in which case the above applies).

'vsstatus.MXR' affects all loads that operate under effective VU-mode or VS-mode:

  • All loads in VU-mode
  • All loads in VS-mode
  • Loads in M-mode when mstatus.MPRV == 1, mstatus.MPV == 1, and mstatus.MPP[1] == 0
  • Loads generated by one of the hlv.* instructions.
SUM18RW

permit Supervisor Memory Access

Allows VS-mode to read user pages.

Applies to the following loads and stores:

  • All loads and stores in VS-mode.
  • All loads and stores in M-mode when mstatus.MPRV == 1, mstatus.MPP == 1, and mstatus.MPV == 1
  • Loads and stores generated by one of the hlv.*, hlvx.*, or hsv.* instructions.

When vsstatus.SUM is 0, the loads and stores from the above categories cause an Illegal Instruction exception if they access a user page during VS-level translation. Otherwise, a load or store from the above categories is permitted to access a user page during VS-level translation.

XS16-15RO

Custom (X) extension context Status

Summarizes the current state of any custom extension state. Either 0 - Off, 1 - Initial, 2 - Clean, 3 - Dirty. Since there are no custom extensions, this field is read-only 0.

FS14-13RW-H

Floating point context status

When 0, floating point instructions (from F and D extensions) in VS-mode or VU-mode are disabled, and cause ILLEGAL INSTRUCTION exceptions. Floating point instructions in all modes, including VS-mode and VU-mode, are similarly disabled when mstatus.FS is clear.

When a floating point register, or the fcsr register is written in VS-mode or VU-mode, vsstatus.FS is written with the value 3.

Values 1 and 2 are valid write values for software, but are not interpreted by hardware other than to possibly enable a previously-disabled floating point unit.

VS10-9RW-H

Vector context status

When 0, vector instructions (from the V extension) are disabled, and cause ILLEGAL INSTRUCTION exceptions. When a vector register or vector CSR is written, VS obtains the value 3. Values 1 and 2 are valid write values for software, but are not interpreted by hardware other than to possibly enable a previously-disabled vector unit.

SPP8RW-H

VS-mode Previous Privilege

Written with the prior nominal privilege level (i.e., 0 for VU-mode and 1 for VS-mode) when entering VS-mode from an exception/interrupt. Can also be written by software without immediate side-effect.

On a return from an exception from VS-mode, the machine will enter the nominal privilege level stored in vsstatus.SPP.

UBE6

VU-mode Big Endian

Controls the endianness of VU-mode (0 = little, 1 = big).

Since the CPU does not support big endian, this is hardwired to 0.

Since the CPU does not support big endian, this is hardwired to 1.

SPIE5RW-H

VS-mode Previous Interrupt Enable

Written by hardware in two cases:

  • Written with prior value of vsstatus.SIE when entering VS-mode from an exception/interrupt.
  • Written with the value 1 when returning from an exception in VS-mode (via the sret instruction).

Can also be written by software without immediate side effect.

Other than serving as a record of nested traps as described above, vsstatus.SPIE does not affect execution.

SIE1RW-H

VS-mode Interrupt Enable

Written by hardware in two cases:

  • Written with the value 0 when entering VS-mode from an exception/interrupt.
  • Written with the prior value of vsstatus.SPIE when returning from an exception in VS-mode (via sret).

Affects execution by:

  • When 0, all VS-mode interrupts are disabled when the current privilege level is VS ((H)S-mode and M-mode interrupts are still enabled).
  • When 1, VS-mode interrupts that are not otherwise disabled with a field in vsie are enabled.

Fields from riscv-unified-db; field types computed by IDL functions there are not shown.