fcvt.s.wu
Floating-Point Convert Unsigned Word to Single-Precision
- Extension
- F
- XLEN
- RV32 and RV64
- Assembly (riscv-unified-db)
fcvt.s.wu fd, xs1, rm- Length
- 32-bit
Encoding
| 3127 | 2625 | 2420 | 1915 | 1412 | 117 | 62 | 10 | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 11010 | 00 | 00001 | rs1 | rm | rd | 10100 | 11 | ||||||||||||||||||||||||
Match 0xd0100053, mask 0xfff0007f. Source: fcvt.s.wu rd rs1 24..20=1 31..27=0x1A rm 26..25=0 6..2=0x14 1..0=3 in riscv-opcodes/extensions/rv_f.
| Field | Bits | riscv-opcodes name |
|---|---|---|
| rs1 | 19:15 | rs1 |
| rm | 14:12 | rm |
| rd | 11:7 | rd |
Description
The fcvt.s.wu instruction converts a 32-bit unsigned integer in integer register xs1 into
a floating-point number in floating-point register fd.
All floating-point to integer and integer to floating-point conversion instructions round
according to the rm field.
A floating-point register can be initialized to floating-point positive zero using
fcvt.s.w rd, x0, which will never set any exception flags.
All floating-point conversion instructions set the Inexact exception flag if the rounded result differs from the operand value and the Invalid exception flag is not set.
Description from riscv-unified-db, reformatted.
Operation
check_f_ok($encoding); RoundingMode rounding_mode = rm_to_mode(rm, $encoding); F[fd] = ui32_to_f32(X[xs1], rounding_mode); mark_f_state_dirty();
Pseudocode in riscv-unified-db’s IDL, quoted unchanged.